Refine Your Search

Topic

Search Results

Technical Paper

A Preliminary Study of the Discharge Current and Spark Energy for the Multi-Coil Offset Strategy

2019-04-02
2019-01-0725
To overcome the unfavorable operation conditions caused by lean/diluted charges in modern Spark Ignited (SI) engines, various advanced ignition systems have been proposed in the past. Among them, the dual-coil and multi-coil Transistor Coil Ignition (TCI) systems with offset discharge strategy caused significant attention in literature because they can generate a continuous spark with high spark energy being delivered into the cylinder. Comparing with the dual-coil system, a multi-coil system is capable to apply more flexible control strategies and generate a higher discharge current. However, the spark energy and transfer efficiency of the multi-coil system are still worthy to investigate as they are important performance indicators for a TCI system. In this paper, the discharge characteristics of the dual-coil and triple-coil strategies under both quiescent and flow conditions were studied firstly by experimental methods.
Journal Article

Impact of Spark Plasma Length on Flame Kernel Development under Flow Condition

2020-04-14
2020-01-1114
Advanced ignition systems with enhanced discharge current have been extensively investigated in research, since they are highly regarded as having the potential to overcome challenges that arise when spark-ignition engines are running under lean or EGR diluted conditions. Local flow field is also of particular importance to improve the ignitability of the air-fuel mixture in SI engines as the spark plasma channel can be stretched by the flow across the spark gap, leading to longer plasma length, thus more thermal spark energy distributed to the air-fuel mixture in the vicinity of the spark plug. Research results have shown that a constantly high discharge current is effective to maintain a stable spark plasma channel with less restrikes and longer plasma holding period.
Technical Paper

Effect of Spark Discharge Duration and Timing on the Combustion Initiation in a Lean Burn SI Engine

2021-04-06
2021-01-0478
Meeting the increasingly stringent emission and fuel efficiency standards is the primary objective of the modern automotive research. Lean/diluted combustion is a promising avenue to realize high-efficiency combustion and reduce emissions in SI engines. Under diluted conditions, the flame propagation speed is reduced because of the reduced charge reactivity. Enhancing in-cylinder charge motion and turbulence, and thereby increasing the flame speed, is a possible way to harness the combustion process in SI engines. However, charge motion can have a significant effect on the spark ignition process because of the reduced discharge duration and frequent restrikes. A longer discharge duration can aid in the formation of a self-sustained flame kernel and subsequent stable ignition. Therefore, an empirical study is undertaken to investigate the effect of discharge duration and ignition timing on the ignition and early combustion in a port fueled SI engine, operated under lean conditions.
Technical Paper

Ion Current Measurement of Diluted Combustion Using a Multi-Electrode Spark Plug

2018-04-03
2018-01-1134
Close-loop feedback combustion control is essential for improving the internal combustion engines to meet the rigorous fuel efficiency demands and emission legislations. A vital part is the combustion sensing technology that diagnoses in-cylinder combustion information promptly, such as using cylinder pressure sensor and ion current measurement. The promptness and fidelity of the diagnostic are particularly important to the potential success of using intra-cycle control for abnormal cycles such as super knocking and misfiring. Many research studies have demonstrated the use of ion-current sensing as feedback signal to control the spark ignition gasoline engines, with the spark gap shared for both ignition and ion-current detection. During the spark glow phase, the sparking current may affect the combustion ion current signal. Moreover, the electrode gap size is optimized for sparking rather than measurement of ion current.
Technical Paper

Oxygenated Fuels as Reductants for Lean NOx Trap Regeneration

2024-04-09
2024-01-2132
The push for environmental protection and sustainability has led to strict emission regulations for automotive manufacturers as evident in EURO VII and 2026 EPA requirements. The challenge lies in maintaining fuel efficiency and simultaneously reducing the carbon footprint while meeting future emission regulations. Alcohol (primarily methanol, ethanol, and butanol) and ether (dimethyl ether) fuels, owing to their comparable energy density to existing fuels, the comparative ease of handling, renewable production, and suitable emission characteristics may present an attractive drop-in replacement, fully or in part as an additive, to the gasoline/diesel fuels, without extensive modifications to the engine geometry. Additionally, lean and diluted combustion are well-researched pathways for efficiency improvement and reduction of engine-out emissions of modern engines.
Technical Paper

Performance of Spark Current Boost System on a Production Engine under Lean-Burn Conditions

2024-04-09
2024-01-2106
In order to improve the fuel economy for future high-efficiency spark ignition engines, the applications of advanced combustion strategies are considered to be beneficial with an overall lean and/or exhaust gas recirculation diluted cylinder charge. Stronger and more reliable ignition sources become more favorable under extreme lean/EGR conditions. Existing research indicates that the frequency of plasma restrikes increases with increased flow velocity and decreased discharge current level, and a higher discharge current can reduce the gap resistance and maintain the stretched plasma for a longer duration under flow conditions. An in-house developed current boost control system provides flexible control of the discharge current level and discharge duration. The current boost ignition system is based on a multi-coil system with a discharge current level of 180mA.
X